Redarc Relay Timer Unit
The TIM05 & TIM06 timers can be used in a 12V or 24V negative ground automotive system, are designed to plug into a standard automotive relay base and have the same pin numbers as a standard automotive relays (underside shown on diagram). Contacts operate in a similar way to a changeover relay.
• The timer switches the internal relay to provide output on PIN 87. (Positive output only)
• The timer is started by switching pin PIN 86 ON or OFF (depending on Switch 1).
• Use Switch 2 to select time range between SECONDS and MINUTES.
• Use the potentiometer to adjust time (increasing in clockwise direction).
The TIM05 & TIM06 can supply a maximum current of 10 AMPS.
Features
Input (Operating) Voltage | 12V/24V |
Output Current Rating | 10A |
Dimensions | 75 x 30 x 24mm |
Weight | 0.07kg |
Manufacturer | Redarc |
---|---|
Rating | Other |
Voltage | Other |
Connector | Other |